Main centres: | 1-3 business days |
Regional areas: | 3-4 business days |
Remote areas: | 3-5 business days |
The ISG1201 unit is a geyser load control timer designed to prevent geysers from operating during designated peak load times in the morning and evening (Monday to Friday, from 06h00 to 08h00 and 18h00 to 20h00).
The ISG1201 is a standalone geyser load control timer suitable for use with hot water geyser tanks. It is simple and quick to install into existing and new distribution (DB) panels and or surface mounted (also suitable for solar applications).
Specifications
Mains Input Power Via Distribution: Input: 220-230VAC 50 Hz
Battery Back-up 5 years
Clock time drift Less than 2min 40 seconds per year
Protection Surge, over-current and reverse polarity
Clock re-programmable Via handheld remote
Mode select Via Keys on face panel
Mode State Via 3Tri colour Led on face panel
Load Control Timer - Load Output Status: Timer Output Status: OFF, 0 V AC, Load OFF.
Timer Output Status: ON, Output 220-230VAC 50 Hz,
via ELC1001 load On.
Override Override ON or OFF: Keypad that will alter the
present load condition if outside of the Eskom Peak.
Load State
Mains Power “ON” Load State = “Green”
Load “ON” Load State = “Red”
Programme selected Load State = “Blue”
Mounting
DIN Rail Surface Mount
Enclosure
IP 50, Protected against dust - limited ingress
(no harmful deposit), fire retardant.
Please view shipping tab before placing your bid